RU EN
Request a quote

Fox ESS · three-phase industrial inverter

Fox ESS R Series (G2) inverter, 75–136 kW

Industrial class for large roofs and ground-mounted plants: up to ten MPPT trackers in a single unit. The array can be split into ten independent groups, which protects yield on complex roof geometry and on tracker fields.

75–136 kW grid-tied 9–10 MPPT up to 98.6% IP66 90 kg

Up to ten trackers

Each string group runs at its own operating point: different pitches, different shading and different module ages do not interfere with each other.

For large sites

From 75 to 136 kW per unit — fewer devices per megawatt, a simpler switchroom and easier maintenance.

IP66 and smart cooling

Operates from −30 to +60 °C and up to 4000 m above sea level (with derating above 3000 m).

Industrial diagnostics

Per-string current monitoring, AFCI and PID recovery — problems show up in the app before they eat into yield.

On requestwholesale price depends on volume
Request a price

Shipped from stock in Krasnodar across Russia. Send us the array size and grid phase configuration — our engineer will check the inverter selection and string layout before dispatch.

Model range and electrical data

← scroll the table →

ModelRated power, kWMax. apparent power, kVAMax. output current, AMPP trackersStrings per tracker
R75-G2 75 82,5 125 9 2
R80-G2 80 88 133,3 9 2
R100-G2 100 110 166,7 9 2
R110-G2 110 121 183,3 10 2
R125-G2 125 137,5 199,3 10 2
R136-G2 136 138 200 10 2

Specifications and operating conditions

← scroll the table →

Max. input voltage 1100 V DC
Start-up voltage 250 V
Rated input voltage 600 V
MPPT voltage range 200–1000 V (550–850 V at full load)
Max. input / short-circuit current per tracker 40 A / 50 A
Efficiency: European / max. 98.2% / 98.6%
Grid 400 V, 3W+N+PE (range 320–480 V) · 45–55 / 55–65 Hz
Power factor / THDi 0.8 leading to 0.8 lagging / <3%
Dimensions (W×H×D) / weight 975 × 630 × 360 mm · 90 kg
Cooling / isolation smart air cooling · non-isolated
Operating conditions −30…+60 °C · up to 4000 m (derating above 3000 m) · IP66
Night consumption 3.5 W
Connections DC — MC4-compatible connectors · AC — OT terminals
Monitoring and communication RS485 / USB / Wi-Fi + LAN / 4G (Bluetooth) · LED, Wi-Fi and app
Protection DC switch, DC reverse polarity, AC short-circuit and overcurrent, type II SPD, PID recovery, insulation and residual current monitoring, AFCI and string current monitoring (optional)
Standards IEC 62109 · IEC 61727 · IEC 62116 · IEC 60068 · IEC 61683 · IEC 61000-6-3 · EN 50549

Documents

Official manufacturer datasheets. Installation manuals and certificates are supplied with the order — ask us and we will send them the same day.

Other series in this group