RU EN
Request a quote

Fox ESS · single-phase grid inverter

Fox ESS F Series (G2) inverter, 3–6 kW

The workhorse for a family home: two independent MPPT trackers let you split the array across two roof pitches with different orientations, and compatibility with the Fox ESS charge controller means storage can be added later without replacing the inverter.

3–6 kW grid-tied 2 MPPT battery ready up to 97.4% IP65

Two pitches, one inverter

Two independent MPPT trackers follow their own strings, so shading or a different orientation on one part of the array does not drag the other down.

Storage can come later

The inverter works with the Fox ESS charge controller. Install a grid-tied system now and add the battery when the customer is ready.

Per-string monitoring

PV string current monitoring shows in the app which string has dropped — no need to climb onto the roof with a meter.

The most common size

The 3–6 kW range covers most family homes on a single-phase supply.

On requestwholesale price depends on volume
Request a price

Shipped from stock in Krasnodar across Russia. Send us the array size and grid phase configuration — our engineer will check the inverter selection and string layout before dispatch.

Model range and electrical data

← scroll the table →

ModelMax. PV array, WRated apparent power, VAMax. apparent power, VARated current, AMax. current, A
F3000-G2 4500 3000 3300 13,0 14,3
F3600-G2 5400 3600 3960 15,7 17,2
F4600-G2 6900 4600 5060 20,0 22,0
F5000-G2 7500 5000 5500 21,7 23,9
F5300-G2 7950 5300 5830 23,0 25,3
F6000-G2 9000 6000 6000 26,1 26,1

Specifications and operating conditions

← scroll the table →

Max. / min. input voltage 600 / 80 V DC
Start-up voltage 120 V
Rated input voltage 360 V
MPPT voltage range 80–550 V
Max. input / short-circuit current 14 A / 18 A
MPP trackers / strings per tracker 2 / 1
Efficiency: MPPT / European / max. 99.0% / 96.8% / 97.4%
Grid 220/230/240 V, 50/60 Hz
Dimensions (W×H×D) / weight 402 × 453 × 148 mm · 14.8 kg
Cooling / topology natural convection · transformerless
Operating conditions −25…+60 °C · up to 3000 m · IP65 · <30 dB
Monitoring and communication LAN / Wi-Fi / GPRS / 4G (optional) · RS485, meter/CT, DRM
Protection insulation monitoring, residual current monitoring, DC reverse polarity protection, anti-islanding, AC short-circuit and overcurrent protection, AC overvoltage protection, PV string current monitoring; type II SPD and DC switch optional
Country of manufacture China
Standards EN/IEC 62109-1/-2 · EN 61000-6-1/2/3/4 · AS/NZS 4777.2 · CEI 0-21

Documents

Official manufacturer datasheets. Installation manuals and certificates are supplied with the order — ask us and we will send them the same day.

Other series in this group