Fox ESS · single-phase hybrid inverter

Fox ESS KH / KA hybrid inverter, 7–10.5 kW

The larger single-phase hybrids: three MPPT trackers, parallel operation of up to ten units and a −40 to +70 °C operating range. KH works with a PV array, KA on the AC side only, as a storage inverter.

7–10.5 kW hybrid and AC 3 MPPT up to 33.24 kWh up to 10 in parallel IP65

Three trackers on a hybrid

An unusual combination: most single-phase hybrids have one or two trackers. Here the array splits into three independent groups.

Scales in parallel

Up to ten inverters in parallel — over 100 kW on a single-phase bus if the site calls for it.

Works in frost and heat

A −40…+70 °C range, among the widest in the line-up. Derating only starts at +45 °C.

99.9% MPPT efficiency

Close to the theoretical limit for maximum power point tracking; peak conversion efficiency is 97.8%.

On requestwholesale price depends on volume
Request a price

Shipped from stock in Krasnodar across Russia. Send us the array size and grid phase configuration — our engineer will check the inverter selection and string layout before dispatch.

Model range and electrical data

← scroll the table →

ModelCharge / dischargeRated AC powerMax. apparent AC powerRated AC current, AMax. AC current, A
KH7 / KA7 7,0 кВт 7000 Вт 7700 ВА 30,4 33,5
KH8 / KA8 8,0 кВт 8000 Вт 8800 ВА 34,8 38,3
KH9 / KA9 9,0 кВт 9000 Вт 9900 ВА 39,1 43,0
KH10 / KA10 10,0 кВт 10000 Вт 10500 ВА 43,5 45,7
KH10.5 / KA10.5 10,5 кВт 10500 Вт 10500 ВА 45,7 47,7

Specifications and operating conditions

← scroll the table →

PV input (KH only) max. 600 V · start-up 75 V · rated 360 V · MPPT 85–480 V
Max. input / short-circuit current 20 A / 16 A per tracker
MPP trackers / strings per tracker 3 / 4
Max. recommended DC power 15,000 W
Battery type lithium-ion, high voltage
Battery voltage / charge-discharge current 85–480 V (300 V recommended) · 50 / 50 A
Storage capacity up to 7 batteries in series — up to 33.24 kWh
Grid 220/230/240 V (range 180–270 V), 50/60 Hz ±5
EPS output (backup) up to 12,000 VA · peak 10,000–12,000 VA for 60 s · switchover <20 ms
Efficiency: MPPT / European / max. 99.9% / 97.4% / 97.8%
Charge (PV→BAT) / discharge (BAT→AC) efficiency 98.5% / 97.0%
Parallel operation up to 10 units
Dimensions (W×H×D) / weight 450 × 527 × 208 mm · 29 kg (KH) / 27.5 kg (KA)
Operating conditions −40…+70 °C (derating from +45 °C) · IP65 · noise <30 dB
Monitoring and communication Wi-Fi, 4G and meter (optional) · RS485, CAN, DRM, USB, CT · 16×4 LCD
Protection PV and battery reverse polarity, anti-islanding, output short circuit, residual current, insulation monitoring, overcurrent and overheat; type II SPD both sides, AFCI optional
Standards IEC 62109-1/-2 · IEC 62477-1 · EN 61000-6-1/2/3 · G99 · EN 50549 · NRS 097-2-1