RU EN
Request a quote

Fox ESS · single-phase grid inverter

Fox ESS S Series (G2) inverter, 0.7–3.3 kW

The most compact single-phase Fox ESS range: seven ratings from 700 W to 3.3 kW in a 5.4 kg housing. A start-up voltage of just 60 volts means the inverter wakes up earlier than most and harvests more at dawn and on overcast days.

0.7–3.3 kW grid-tied 1 MPPT up to 97.4% IP65 5.4 kg

Very low start-up threshold

A 60 V start-up voltage against the typical 120–140 V: the array starts exporting earlier and stops later.

Fits anywhere

Five and a half kilograms in a 29×22 cm housing — one person mounts it, and it fits a narrow recess or a switchboard wall.

For small sites

Cabins, garages, kiosks, pump stations and lighting systems — wherever the array is only a few modules.

Weatherproof

IP65 and a −25…+60 °C operating range: it can go outdoors without an extra enclosure.

On requestwholesale price depends on volume
Request a price

Shipped from stock in Krasnodar across Russia. Send us the array size and grid phase configuration — our engineer will check the inverter selection and string layout before dispatch.

Model range and electrical data

← scroll the table →

ModelMax. PV array, WRated power, WMax. apparent power, VARated current, AMax. current, AEuropean efficiencyMax. efficiency
S700-G2 1050 700 800 3,0 3,5 96,50% 97,20%
S1000-G2 1500 1000 1100 4,3 4,8 96,50% 97,20%
S1500-G2 2250 1500 1650 6,5 7,2 96,50% 97,30%
S2000-G2 3000 2000 2200 8,7 9,6 96,80% 97,40%
S2500-G2 3750 2500 2750 10,9 12,0 96,80% 97,40%
S3000-G2 4500 3000 3300 13,0 14,3 96,80% 97,40%
S3300-G2 4950 3300 3300 14,3 14,3 96,80% 97,40%

Specifications and operating conditions

← scroll the table →

Max. input voltage 500 V DC
Start-up voltage 60 V
Rated input voltage 360 V
MPPT voltage range 50–480 V
Max. input / short-circuit current 14 A / 18 A
MPP trackers / strings per tracker 1 / 1
MPPT efficiency 99.0%
Grid 220/230/240 V, 50/60 Hz
Power factor / THDi 1 (adjustable to 0.8) / <3%
Dimensions (W×H×D) 290 × 220 × 116 mm
Weight 5.4 kg
Cooling / topology natural convection · transformerless
Operating conditions −25…+60 °C · up to 3000 m · 0–100% RH non-condensing
Ingress protection / noise IP65 · <30 dB
Night consumption <1 W
Monitoring and communication Wi-Fi / 4G (optional) · RS485, meter/CT · LCD, app, web portal
Protection insulation monitoring, residual current monitoring, DC reverse polarity protection, anti-islanding, AC short-circuit and overcurrent protection, AC overvoltage protection; type II SPD, DC switch and AFCI optional
Standards EN 62109-1/-2 · IEC 61727 · IEC 62116 · EN 50549-1 · VDE V 0126-1-1 · G98

Documents

Official manufacturer datasheets. Installation manuals and certificates are supplied with the order — ask us and we will send them the same day.

Other series in this group